Hanna PH Portable Meter HI-9126
Product SKU : HI-9126
Country : USA
The HI 9126 is the next generation in professional, accurate, easy-to-use pH meters. Designed to provide laboratory results in a sleek, portable design. The HI 9126 features HANNA‘s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH bulb, Calibration Check™ prompts the user that additional cleaning may be needed.
The extended multi-level LCD displays pH and temperature (°C or °F) readings simultaneously, while also displaying the electrode status and operational guides. The HI 9126 helps users through the calibration process with clear on-screen messages. The meter features a series of diagnostic features to improve measurement consistency and reliability.
Calibration is performed automatically at 1 or 2 points with 7 standard buffers and 2 custom buffers.
HI 9126 is supplied with rechargeable batteries and a inductive docking station for easy recharging.
The meter is provided with the BEPS (Battery Error Prevention System) which automatically turns the instrument off when the battery level is too low to ensure reliable readings.
The HI 9126 can also be used for ORP measurements in the mV range with 0.1 mV resolution.
Contact Us
09-5025972, 09-400980820, 09-403997605
This email address is being protected from spambots. You need JavaScript enabled to view it.
This email address is being protected from spambots. You need JavaScript enabled to view it.
Range | ||
pH | : | -2.00 to 16.00 pH -2.00 to 16.00 pH |
mV | : | ±699.9 mV |
Temperature | : | -20.0 to 120.0°C / -4.0°F to 248.0°F |
Resolution | ||
pH | : | 0.01 pH |
mV | : | 0.1 mV; 1 mV |
Temperature | : | 0.1°C / 0.1 °F |
Accuracy (@20°C) | ||
pH | : | ±0.01 pH |
mV | : | ±0.2 mV; ±1 mV |
Temperature | : | ±0.4°C / ±0.8°F |
pH Calibration | : | automatic, 1 or 2 point with 7 standard buffer values (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers |
Offset Calibration | : | ±1 pH |
Slope Calibration | : | From 80 to 108% |
Temperature Compensation | : | automatic or manual, -20 to 120°C (-4 to 248°F) |
pH Electrode | : | HI 1230B, double junction, gel filled, BNC connector and 1 m (3.3’) cable (included) |
Temperature Probe | : | HI 7662 with 1 m (3.3’) cable (included) |
Input Impedance | : | 1012 Ohm |
Battery Type / Life | : | (4) 1.2V AAA rechargeable / approx. 200 hours of continuous use (with backlight off ); auto-off after 20 minutes of non-use (can be disabled) |
Environment | : | 0 to 50°C (32 to 122°F); RH max 100% |
Dimensions / Weight | : | 192 x 71.6 x 36 mm (7.5 x 2.8 x 1.4’’) / 525 g (18.5 oz.) |